Erfolgix 7000S Battery Monitoring System: gateway, sensors and dashboardErfolgix 7000S Battery Monitoring System. Smarter monitoring, longer life, higher reliabilityErfolgix 7000S Battery Monitoring System
Erfolgix 7000S

Battery Monitoring System for Lead Acid & Ni-Cd Batteries

Battery type: For Lead acid and Nickel Cadmium Batteries

An intelligent gateway, cell sensors and string sensors working together to bring every battery in your bank into one live dashboard, with real-time viewing, historical records, graph analysis and 24/7 alarm management.

View SpecificationsDownload Datasheet

New to battery monitoring? Learn why monitoring every cell matters for UPS, telecom, utility and data-centre backup power.

Introduction to Battery Monitoring →
Erfolgix 7000S system: gateway, cell sensor, string sensor and HMI
Why it matters

Cell-level battery monitoring: see every battery, not just the string

In a series string, the weakest battery sets the limit. The 7000S measures each cell or block individually so a weak unit is found early, before it costs you backup time.

V

Cell-level measurement

Voltage, temperature and internal impedance (ohmic value) for every BS - 2V, BS - 12V and BS - 1.2V battery, with a balancing function on supported sensors.

A

String-level insight

String voltage and current, SOC and SOH calculation, and charge or discharge status for each battery string.

!

Alarms that act

Upper and lower limit alarms for cell voltage, temperature, internal impedance and SOC, with voice, SMS, e-mail and sound-light routing.

System components

7000S system components: cell sensors, string sensors, gateway and HMI

Erfolgix cell sensor for 12 volt battery BS-12V and 2 volt cell sensor BS-2V

Cell Sensor BS-12V / BS-2V

Cell sensor for 12 volt battery (BS-12V) and for 2 volt cells (BS-2V), one sensor per battery block.

  • Voltage, temperature, impedance
  • Balancing function
Erfolgix String Current Detect Module AM and String Voltage Detect Module UM with Hall sensor

String Sensors AM & UM

String Current Detect Module – AM and String Voltage Detect Module – UM, with Hall sensor options.

  • Each connects 60–70 cell sensors
  • SOC, SOH, charge status
Erfolgix 7000S BMS-Gate: gateway BMS for lead acid 12V batteries, 1U rack unit

7000S Gateway (BMS-Gate)

Gateway BMS for lead acid 12V batteries and 2V cells: monitor control gateway with built-in web server.

  • Ripple voltage, discharge graphs
Erfolgix 10 inch touch panel HMI configured with BMS-Gate showing cell-by-cell battery status

10-Inch Touch Panel HMI

10 inch touch panel HMI configured with BMS-Gate to monitor battery parameters in real time on site.

  • Cell-by-cell bar view
  • Instant exception visibility

System at a glance

Erfolgix 7000S components: gateway, HMI, AM / UM modules, Hall sensors and BS-12V cell sensors

The 7000S is a complete gateway BMS for lead acid 12V batteries, 2V cells and nickel cadmium banks. Each component below appears in the order information.

ComponentOrder codeRole in the system
Gateway BMS (BMS-Gate)GatewayMonitor control gateway with web view: collects data from all string and cell sensors, raises alarms and connects to UPS, SCADA and the network.
10 inch touch panel HMIHMITouch panel configured with BMS-Gate to show battery parameters in real time at the battery room.
String Current Detect Module – AMAMMeasures string charge and discharge current through a Hall sensor.
String Voltage Detect Module – UMUMMeasures total string voltage, 8 to 1000 VDC.
Hall sensorHall SensorCurrent transducer for the AM module, offered as Hall sensor-50A, -200A, -400A and -800A.
Cell sensor for 12 volt batteryBS-12VOne-to-one sensor for each 12 V block: voltage, temperature and internal resistance.
Cell sensor for 2 volt batteryBS-2VOne-to-one sensor for each 2 V cell: voltage, temperature and internal resistance.

Full ranges and accuracies are in the technical specifications and the 7000S datasheet.

Software

Battery monitoring software: dashboards that tell you what to do next

Erfolgix battery monitoring software: real-time cell status dashboard

Live string status, cell-level comparison and instant visibility of low or high cells.

Erfolgix battery monitoring software: historical voltage trend dashboard

Voltage trend lines and comparative measurements to track battery-life deterioration over time.

Gateway features

Gateway features: Modbus integration, data logging and export

Built for integration with your UPS, SCADA, building management and network environment, so battery data and alarms reach the right team.

Communication

6 RS485 ports with Modbus and 2 Ethernet ports for data and alarms.

Web access

Built-in web server with web-view pages.

Data and export

8 GB SD card, 12 months logging, export JPG, PDF and XLS.

Reporting

Real-time and historical records with graph analysis.

Technical data

7000S technical specifications and ordering information

Sensors: functions and records

SensorDescriptionMonitors & records
Cell sensor
BS-2V Cell / BS-12V Cell
One-to-one cell sensor for 2 V or 12 V batteries, block stethoscopeCell voltage
Cell temperature
Cell internal impedance (ohmic value)
Balancing function (only for 2V Cell-A & BS 12V Cell-B)
String sensor
AM
String current: 1 Hall sensor −1000 ~ 1000 A; 2 Hall sensor −2000 A (±2.0%, 15 °C ~ 35 °C)String voltage, string current
SOC & SOH
Balancing function extends battery life
Batch set address
Judge charging and discharging status
Each BMS string sensor max. connects 60~70 pc BMS-2V Cell / BMS-12V Cell
String sensor
UM
String voltage: 8 ~ 1000VDC (±0.5%), battery string stethoscope

Technical specifications

ItemVoltageTemperatureInternal resistancePower consumption
BS-2V Cell1.6V to 2.6V (±0.2%)−20 °C to +85 °C (±1.0 °C)0.1 mΩ to 100 mΩ
Repeatability error: 1.0% + 25 µΩ
Conformity error: 1.5% + 25 µΩ
Running: 170 mW
Sleeping: 12 mW
BS-12V Cell7.5V to 15.6V (±0.2%)Running: 120 mW
Sleeping: 10 mW
UM24VDC (range: 9~32VDC)Working temperature: −15 °C ~ +55 °C
Humidity: 5% ~ 95% RH
Power consumption: <1 W
AMPower consumption: <0.5 W

1. All specifications are subject to change without prior notice. 2. Data in this datasheet are typical values for reference only, not as a basis for engineering design.

Gateway hardware specifications

ItemSpecificationItemSpecification
CPUARM Cortex-A7 528MHzMemory512MB DDR3
ROMeMMC 4G + SD Card 8GCommunications1 RS485, Baud Rate 9600, 19200, 38400bps (optional), Half Duplex
Ethernet Port2x10/100M Ethernet PortPower Supply2 x AC 220V, Range: AC85~264V/DC120-370V
DI6 DI, Passive switch inputDO6 DO, 250VAC/5A or 30VDC/5A
Consumption< 15WPower Supply2 x AC 220V, Range: AC85~264V/DC120-370V
Working Temp−15 °C ~ +60 °CStorage Temp−40 °C ~ +70 °C
Humidity10-95% RH, No condensationL*W*H430mm x 200mm x 44mm, Standard 1U device (19 inches)

1. All specifications are subject to change without prior notice. 2. Data in this datasheet are typical values for reference only, not as a basis for engineering design.

Order information

System structureOrder codeDescription
Communication LayerGatewayMonitor Control Gateway with Web View
DisplayHMIMonitor battery parameters in real time
String SensorAMString current: 1 Hall sensor: −1000 ~ 1000A, 2 Hall sensor: −2000 ~ 2000A (±2.0%, 15 °C ~ 35 °C)
String SensorUMString voltage: 8 ~ 1000VDC (±0.5%)
String SensorHall SensorHall sensor-50A (Rated input: 50A, Measure range: 0~+100A, Φ20mm)
Hall sensor-200A (Rated input: 100A, Measure range: 0~+120A, Φ40mm)
Hall sensor-400A (Rated input: 200A, Measure range: 0~+400A, Φ40mm)
Hall sensor-800A (Rated input: 400A, Measure range: 0~+800A, Φ40mm)
Cell SensorBS-2V2 volt battery One-One cell sensor
Cell SensorBS-12V12 volt battery One-One cell sensor

1. All specifications are subject to change without prior notice. 2. Data in this datasheet are typical values for reference only, not as a basis for engineering design.

System architecture

System architecture: 7000S gateway, BMS-CM and BMS-VM string sensors, cell sensors, HMI, web, mobile app and CMS management

BMS implementation checklist

01

Battery type & battery bank configurationType of battery, number of strings, cells per string, nominal DC voltage and installation layout

02

Monitoring parametersVoltage, temperature, internal resistance, ripple, SOC / SOH / SOP

03

Interfaces & integrationUPS, SCADA / BMS platform, network and alarm routing

04

System requirements & scopeProtection ratings, communications, power supply, reporting and commissioning scope

05

Site & environmental conditionsTemperature, humidity, leakage and grounding

Applications

Battery monitoring for UPS, data centres, telecom and utilities

The 7000S protects the backup batteries behind critical operations. Each application has its own guide.

Erfolgix supplies the 7000S battery monitoring system and related battery monitoring solutions and products from Dubai to projects in the UAE (Dubai, Abu Dhabi, Sharjah), Saudi Arabia, Qatar, Kuwait, Bahrain, Oman and India, and to customers across the globe. Request a quotation with your battery type and bank configuration.

FAQ

7000S battery monitoring system FAQ

What is included in the Erfolgix 7000S gateway BMS for lead acid 12V batteries?

A typical 7000S system includes the BMS-Gate gateway, a 10 inch touch panel HMI configured with BMS-Gate, the String Current Detect Module – AM with a Hall sensor, the String Voltage Detect Module – UM, and one cell sensor per battery: BS-12V for 12 volt batteries or BS-2V for 2 volt cells.

What do the String Current Detect Module – AM and String Voltage Detect Module – UM do?

The AM module measures string current through Hall sensors (1 Hall sensor −1000 to 1000 A; 2 Hall sensors −2000 to 2000 A, ±2.0%). The UM module measures string voltage from 8 to 1000 VDC (±0.5%). Together they provide string voltage, string current, SOC, SOH and charge / discharge status.

Which Hall sensor sizes are available for the 7000S?

Hall sensors are offered as Hall sensor-50A (measure range 0 to +100 A, Φ20 mm), Hall sensor-200A (0 to +120 A, Φ40 mm), Hall sensor-400A (0 to +400 A, Φ40 mm) and Hall sensor-800A (0 to +800 A, Φ40 mm), as listed in the order information.

What is the cell sensor for 12 volt battery BS-12V?

The BS-12V is a one-to-one cell sensor fitted to each 12 V battery block. It measures block voltage from 7.5 V to 15.6 V (±0.2%), temperature from −20 °C to +85 °C and internal resistance from 0.1 mΩ to 100 mΩ, with a balancing function on the BS 12V Cell-B version.

Which battery types does the Erfolgix 7000S battery monitoring system support?

The Erfolgix 7000S is designed for lead acid (including VRLA) and nickel cadmium (Ni-Cd) battery banks. Cell sensors are available as BS-2V for 2 V cells and BS-12V for 12 V blocks, with one sensor fitted to each cell or block. See the 7000S specifications.

What parameters does the 7000S battery monitoring system measure?

At cell level it measures cell voltage, cell temperature and cell internal impedance (ohmic value). At string level it measures string voltage and string current, calculates SOC and SOH, and works out whether the string is charging or discharging. The gateway also records ripple voltage and discharge graphs.

How accurate are the 7000S cell sensors?

The BS-2V cell sensor measures 1.6 V to 2.6 V (±0.2%) and the BS-12V measures 7.5 V to 15.6 V (±0.2%). Both measure temperature from −20 °C to +85 °C (±1.0 °C) and internal resistance from 0.1 mΩ to 100 mΩ. These are typical datasheet values for reference.

How many cell sensors can one string sensor connect?

Each string sensor connects up to 60–70 cell sensors. The AM string sensor measures string current (1 Hall sensor −1000 to 1000 A; 2 Hall sensors up to −2000 to 2000 A) and the UM string sensor measures string voltage from 8 to 1000 VDC (±0.5%).

How does the 7000S send alarms?

You can set upper and lower limit alarms for cell voltage, temperature, internal impedance and SOC. Alarms can be routed by voice, SMS, e-mail and sound-light, and the gateway has relay outputs (DO) for connection to site alarm systems.

Can the 7000S integrate with UPS, SCADA or a building management system?

Yes. The gateway communicates over RS485 with Modbus and over Ethernet, and has a built-in web server for browser access. It is designed to integrate with UPS, SCADA and network environments.

How long is battery data stored and can it be exported?

The gateway logs 12 months of data on an 8 GB SD card. Real-time and historical records, trends and graphs can be exported as JPG, PDF or XLS files for reports and maintenance records.

Does Erfolgix supply the 7000S in the UAE, the GCC, India and worldwide?

Yes. Erfolgix is based in Dubai Silicon Oasis and serves customers across the UAE, Saudi Arabia, Qatar, Kuwait, Bahrain, Oman and India, and supplies its battery monitoring solutions and products to all countries worldwide. Contact us for project sizing and a quotation.

More answers in our FAQ.

Planning a battery monitoring project?

Share your battery type and monitoring needs.

Contact UsDownloads
Downloads

Erfolgix 7000S battery monitoring system datasheet

Document nameDownload
Erfolgix 7000S Battery Monitoring System: Datasheet (PDF)Download